Establishing an accurate calibration for a series of
elements in a product is a tedious and costly exercise. The use of a stable
monitor means that the calibration procedure need only be carried out at long
intervals. The monitors listed below have been formulated so that they have
appropriate count rates when analysing the different ores and products. The
monitors contain little flux and should have good long-term stability. Most
monitor types have been in use for many years. They are polished flat so that they can be mounted precisely and are
easily cleaned.
Please note that the monitors are not certified for
actual concentration values and as such there is no certificate provided. The monitor is designed for instrument drift correction and as such
provides a stable matrix and representative count rates rather than a particular
concentration. They are available as 40 mm disks only.
AUSMON for
SILICATES and general use.
These monitors were
designed for the analysis of rocks, soils and related
materials.
They can also be used as
general purpose monitors for analysing a wide range of materials, eg.
vegetables, etc.They contain the following elements as majors: Fe, Mn, Ti, Ca,
K, Cl, S, P, Si, Al, Mg, Na and F.
In addition about 2000ppm
of each of the following are present: Sc(1000ppm), V, Cr, Co, Cu, Ni, Zn, Ga,
Ge, Se, As, Rb, Sr, Br, Y, Zr, Nb, Mo, Ag, Cd, Sn, Sb, Te, Cs, Ba, La, Ce, Nd,
Pr, Yb, Hf, Ta, W, Bi, Tl, Pb, Th, and U. (51 elements).
|
IRON
ORES
These are formulated
for use in the analysis of iron ores and related materials.
The following elements
are present: Fe, Si, Al, Ca, F, Na, Mg, P, S, Cl, K, Ti, V, Cr, Mn, Co, Ni, Cu,
Zn, As, Br, Sn, Cd, Sb, Bi, Mo, Ba, and Pb. (28 elements)
|
|
MINERAL
SANDS
These monitors have been
prepared for use when analysing mineral sand products, eg. ilmenite, rutile,
zircon, monazite and xenotime.
The following elements
are present: Ti, Fe, Zr, Si, Y, La, Ce, Nd, Pr , Yb, P, F, Na, Mg, Al, S, Cl, K,
Ca, Sc, V, Mn, Cr, Co, Ni, Cu, Zn, Br, As, Sr, Nb, Mo, Cd, Sn, Ba, Hf, Pb, Th,
and U. (39 elements).
|
|
CEMENT
Monitors prepared for
analysing cement and related materials contain: Ca, Si, Al, Mg, Fe, Na, Cl, S,
F, P, K, Ti, Cr, Mn, Zn, Sr, Br, Ba, and Pb. (19 elements)
|
|
HIGH NI
PRODUCTS
These monitors are
for use with nickel ores and related materials. The following elements
are present: Ni, Fe, S, Si, F, Na, Mg, Al, P, Cl, K, Ca, Ti, Mn, Cr, Co, Cu, Zn,
As, Se, Br, Mo, Ag, Pb, and Bi. (25 elements).
|
|
MANGANESE
ORES
These monitors are
for use when analysing manganese ores. hey contain: Mn, Fe,
Si, Na, Mg, Al, P, K, Ca, Ti, V, Sr, Br, and Ba, Pb. . (15
elements).
|
|
LEAD,
ZINC, IRON, and COPPER SULFIDES.
These monitors
are for use with lead, zinc, iron and copper sulphides, as ores, concentrations
and related products. They contain:
Pb, Zn, Fe, Cu, S, F, Na, Mg, Al, Si, P, K, Ca, Cl, Ti, Co, Ni, Cr, Mn, As, Sr,
Se, Ag, Cd, Sn, Sb, Ba, Te, Tl, Mo, U, and Bi. (32
elements).
|
|
RARE
EARTHS
These monitors are to be
used when analysing monazite, xenotime and other rare earth minerals for the
rare earth oxides. They contain: La, Ce, Pr,
Nd, Sm, Eu, Gd, Tb, Dy, Ho, Er, Tm, Yb, Lu, Y, P, F, Na, Mg, Al, Si, S, Cl, K,
Ca, Sc, Ti, Mn, Fe, Ni, Br, Sr, Zr, Nb, Ba, Hf, Pb, Th, and U. (39
elements).
|
|
HERASIL DISK
(Blank)
High Purity Glass
disk.
|
|