LABFIT

LabFit manufacture innovative and reliable pH, Carbon & Sulphur and Thermogravimetric analysers. They will also customise instruments and software to suit client applications. With 10 years experience and customers worldwide they are leaders in their field.

AS-3000 Series Automated pH Analyzers

The automated AS-3000 analysers provide consistent results and eliminates inherent operator errors which are unavoidable doing pH & EC’s manually. Each sample is consistently handled in exactly the same manner. It will only record results according to programmable settings. 

  • The AS3000 is extremely reliable, easy to set up and most problems can be solved in house
  • High Sample throughput  ~ 1,200 samples per eight hour shift
  • More accurate results – AS-3000 analyses samples according to programmed settings
  • Minimal operator intervention required 

Models include

  • AS-3000 Single pH
  • AS-3020 pH & EC
  • AS-3100 pH, EC & ORP (Redox)
  • AS-3200 pH, EC & Titrations
  • AS-3000D dual pH
  • AS-3300 Autoweigh System (LOI)
  • AS-3360 Suspended Solids
  • AS-3500 Oil Dispenser & Dilutor
  • AS-3400 Fluoride Analyser
  • AS-3010D Dual pH with quad Stirrers 

Instrument configurations include

  • 1 Tray Configuration
  • 3 Tray Configuration
  • Single or Dual Syringe Pump option for Buffer additions

Soil testing accessories include

  • Automatic Washpot for AS-3000
  • Water Dispensing Systems
  • Buffer Pumps for AS-3000
  • Automatic Probe Rising system to prevent sample cross contamination available in single, dual or quad configurations.
  • The SP-100 dispensing pump quickly adds water to sample cups, is fully adjustable from 0-80ml and cycles dispensing once started
  • The AS-3000 Buffer Pump connects directly to the software to automatically add buffers to samples and there are many syringe sizes available. 

LabFit will also customise instruments and software to suit client applications

 

Back to the Top of the Page

CS-2000 series Carbon & Sulphur Analysers

The LabFit automated carbon and dual range sulphur analysers are suitable for coal, coke, oil, cement, catalyst, mineral ores, soils and plants. The simplified cabinet layout provides easy access to mechanical parts such as the pressure gauges, regulators, flow meters, flow controller and the vacuum pump and the automatic sample loader is easy to maintain.

Reliability is inbuilt due to the use of only 3 PCB boards reducing the likelihood of electronic faults and the robust mechanical design results in more reliable operation with a simplified flow system which reduces blockages and a proven reliable vertical combustion system. 

Vertical Resistance Furnace

  • Less thermal shocks - reducing breakages
  • Longer heating element life span
  • Easy to change ceramic tubes
  • Insulation rated to 1600°C - less radiant heat 

Automatic sample loader / unloader

  • Samples are picked up from the carousel and returned to original positions
  • Crucibles are not simply dropped into a bucket 

Calibration of the CS-2000

  • Multipoint Calibration Techniques
  • Ability to use previous results
  • Display of Statistical Data
  • Sample plotted on calibration curve
  • Ability to identify bad standards
  • IR Cells are factory linearised  

Analysing samples made easy

  • Easy sample entry for unskilled operators
  • Data import from LIMS
  • Detailed method description for operators
  • Ability to select output format to printer or LIMS
  • QC samples can be included with Production Samples 

Entering samples

  • Features smart copy , repeat & undo
  • Weight automatically transferred
  • Able to do “spot” samples
  • 5 carousels of data
  • Sample Information

Back to the Top of the Page

TGA-4000 Robotic Thermogravimetric Analyser

The top of the line in thermogravimetric analysers or TGA, is the TGA-4000. It offers a cost effective method of doing Loss on Ignition (LOI) on materials such as Iron Ore, Bauxites and other Mineral Ores with minimal operator involvement. The system is designed to provide high throughput TGA results with a capacity to analyze over 1,200 samples in a 24 hour period.

The self contained robotic cell consists of a robot, drying cabinet, carousel loading cabinet, four furnaces and a crucible cooling station and is designed to perform loss on ignition using different temperatures to achieve a 4 point LOI. The furnaces can be programmed to operate at temperatures between 100 and 1000°C and are permanently kept at the programmed temperature.

The Robot performs all the tasks usually undertaken by operators such as loading and unloading the Carousels.

The TGA-4000 is programmed to maximise sample throughput by ensuring that all ovens are fully utilized. For safety reasons the robot cell is fully enclosed. The entire system is PC driven and has the ability to import and export data to and from most LIMS Systems. It has a powerful and intuitive user interface that allows the operator to perform all functions of the analysis.