Sietronics Logo Supplier's Logos

Furnaces

SEM Muffle Furnace

SEM Muffle Furnace 1150°C

Furnaces can be supplied with either sliding or cantilever type door. The quick action sliding door can be held in any position and is ideal for ashing or similar operations. A cantilever door has an outward and upward swing with a counter-balanced handle on the right hand side or left hand side optional.

The furnaces are strongly constructed of zinc coated steel, powder coated Wedgewood blue with Hi Temp black front face and door. The muffle is strongly supported by a refractory mould at the front and insulating bricks at the back. It is insulated with top grade ceramic fibre blanket or non-hazardous substitutes on request. The steel cover around the muffle is surrounded by an air cavity and by gravity convection draws heat away from the bottom and out through the top reducing the wall temperature of the outer body. An air gap at the front and louvres on back panel allow adequate air flow to ensure a cool instrument panel. All cantilever door furnaces are fitted with a door switch for safety.

Kanthal A1 Element is controlled by a microprocessor based PID Controller complete with Auto Tune function and sensor compensation for accurate temperature control. An overtemp cutout is also provided as a standard feature.

Optional Extras

Furnace Details

Model100 Series150 Series200 Series
Power Ratings2400 W3600 W4800 W
Cat# Cantilever Door102C152C202C
Cat# Sliding Door102S152S202S
External (mm)456Dx468Wx560H500Dx470Wx610H608Dx546Wx630H
Internal (mm)250Dx160Wx90H290Dx170Wx135H435Dx230Wx150H
Weight (kg)505670
Capacity (ltr)3.56.615

SEM Ashing Furnace

SEM Ashing Furnace 1000°C

The furnaces are strongly constructed of zinc coated steel powder coated Wedgewood blue with Hi Temp black front face and door. The muffle is strongly supported by a refractory mould at the front and insulating bricks at the back. It is insulated with ceramic fibre and firebricks. The steel cover around the muffle is surrounded by an air cavity and by gravity convection draws heat away from the bottom and out through the top reducing the wall temperature of the outer body. An air gap at the front and louvres on back panel allow adequate air flow to ensure a cool instrument panel. All cantilever door furnaces are fitted with a door switch for safety.

Air exhaust is through an adjustable 50mm vent on top of the furnace. Airflow is up to 20 exchanges per minute at 800°C. The air inlet is through two vent tubes at the back of the furnace allowing air to pass over the external surface of the muffle through channels in the insulating bricks and into the working chamber via a gap at the top of the muffle. This gives a preheated airflow to maintain an even temperature. The heating section of muffle is set back from the door face approximately 70mm to give an even temperature from front to back of working area. The outer case is kept to minimum temperature by a surrounding air cavity.

Kanthal A1 Element is controlled by a microprocessor based PID controller complete with Auto Tune function and sensor compensation for accurate temperature control. An overtemp cutout is also provided as a standard feature.

Furnace Details

Model100 Series
Power Ratings240V 2400 W
Cat#102CAF
External (mm)460D x 475W x 560H
Internal (mm)320D x 160W x 90H
Weight (kg)70
Temp RangeAmbient to 1000°C ±2°C
Temp Variation±10°C @ 815°C*
Rate of Ventilation2-20 Exchanges per minute @ 800°C

*Applies to uniform zone within 30mm of back & 70mm from front edge of muffle liner

SEM Volatile Matter Furnace

SEM Volatile Matter Furnace

The furnace has three thermocouples. A permanently fixed stainless steel sheathed thermocouple which controls the temperature of the muffle. A ceramic sheathed thermocouple permanently located so as to position the four place crucible stand in the uniform temperature zone, and an unsheathed thermocouple which can be positioned under any of the four crucibles. The temperature of the unsheathed thermocouple is related to the sheathed thermocouple and must be 900± 5°C. Both of these thermocouples are terminated on the front panel of the furnace for easy monitoring. The furnace has adequate heating to regain 885°C after four minutes and 900± 5°C within seven minutes of the insertion of a cold stand and it's crucibles, as required by the standard. A four place crucible stand, flue cap and floor tile are provided with the furnace.

Kanthal A1 Element is controlled by a microprocessor based PID Controller complete with Auto Tune function and sensor compensation for accurate temperature control. An overtemp cutout is also provided as a standard feature.

Strongly constructed of zinc coated steel powder coated Wedgewood blue with Hi Temp black front face door. The muffle is supported by a refractory mould at the front and insulating bricks at the back. It is insulated with top grade Kaowool ceramic fibre blanket. The steel cover around the muffle is surrounded by an air cavity and by gravity convection draws heat away from the bottom and out through the top reducing the wall temperature of the outer body. An air gap at the front and louvres on back panel allow adequate air flow to ensure a cool instrument panel. All cantilever door furnaces are fitted with a door switch for safety.

Optional Extras

Furnace Details

Model100 Series
Power Ratings2400 W
Cat#102VM
External (mm)456D x 468W x 560H
Internal (mm)250D x 160W x 90H
Weight (kg)50